Organization or Activity
Relevant Requirements or Standards
Calibration Considerations
Medical device manufacturing
FDA QMSR / ISO 13485:2016
Control of monitoring and measuring equipment, calibration identification, and records
Pharmaceutical manufacturing
21 CFR Part 211
Written calibration programs, suitable intervals, equipment controls, and records
Testing and calibration laboratories
ISO/IEC 17025:2017, where applicable
Equipment status identification, calibration programs, metrological traceability, and records
Biotechnology operations
Requirements vary by regulated activity
Calibration controls based on applicable manufacturing, testing, and quality system requirements
Calibration procedure or method used.
Reference standards and their associated traceability information.
Measurement results and applicable tolerances.
As-found and as-left results, where required.
Adjustments or repairs performed.
Personnel or service provider responsible for calibration.
Calibration status and any limitations.
Next calibration due date or approved calibration interval.
Label Information
Purpose
Equipment ID
Connects the instrument to its digital or physical records
Calibration Date
Identifies when calibration was performed
Next Due Date
Communicates the next scheduled calibration
Calibration Status
Indicates whether the equipment is approved, restricted, or out of service
Technician Identification
Identifies the person or provider responsible
Barcode or QR Code
Provides a reference to associated digital equipment information
Not every field is required on every calibration label.
This workflow helps prevent equipment from displaying an approved status before the associated calibration results have been reviewed and accepted.
Missing equipment identifiers: Instruments cannot be reliably connected to their calibration histories.
Incomplete calibration records: Required results, acceptance criteria, or supporting documentation are missing.
Overdue equipment without appropriate controls: Instruments remain accessible for routine use after their approved calibration interval has expired.
Outdated status labels: Equipment has been restricted in the CMMS, but the physical label still indicates approved status.
Uncontrolled record changes: Calibration information can be modified without appropriate authorization or documentation.